LT Control™ Application Controller Product Support
Below are the support materials available for the LT Control™ Application Controller.
A: Turn the master switch to the Off position, hold the Blast button, and turn the vehicle on.
A: Turn the master switch to the Off position before turning the vehicle on. E1 indicates the master switch is in the Manual or Auto position.
A: Turn the dial all the way to the right, and the saturation point will flash up. Turn it back to the left (zero), and the offset point will flash up. Both are in percentages from 0-100 (100=00).
A: The left decimal point will light up when setting the offset, and the right decimal point will light up when setting the saturation point.
A: SFCC15 cartridges should be set at 250hz (LT comes programmed this way). The HydraForce should be set at 110hz.
A: Enter calibrate mode and minimize the saturation point of the spinner valve to the desired speed.
A: The ground speed has not been set in the calibrate mode. Redo the ground speed set point. If this doesn’t work, check the speedometer cable connections, then replace the speedometer cable.
A: You can lower the maximum speed by decreasing the saturation point. If the conveyor is turning too fast at the lowest dial setting, then you need to lower the offset point.
A: Valve is sticking or the offset point is set too high.
A: You must operate in auto mode and have the ground speed reference point set into the LT Control™ Application Controller.